Keston Spa Installation Manual Page 10

  • Download
  • Add to my manuals
  • Print
  • Page
    / 12
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 9
Cut out
lmmersion
HeaterWring
Connect Live
to
thermostat
Heat resisting
cable
from Double Pole
isolating
switch
Connect
Earth
Connect
Neutral
-
Hand
guarantee
card to
user.
8.
Electrical
Specification
& Wiring
(lmmersion
Heater)
-
Element
terminals are marked
N(Neutral)
and L(Live)
-
Ensure
earth connection
of 3 wire
supply
is connected
to
earth.
-
Recommended
supply for
3kW element is
2.5mm
cable
to
85614l
-
A 16 Amp
timer is recommended
for
3kW
elements
-The
unit is not fitted with
a fuse.
-
All heating
elements
operate
on a 230 VAC
50Hz
mains
supply. Do
not fit immersion
heate(s)
without
thermal
cutout(s).
FUSE
RATING:
The fuse
rating
for two
3kW
immersion
heaters
wired
separately
from
the main fuseboard
should
be l5
Amps.
Electrical
Wiring
Drawing
Cylinder
Thermostat
From Timeclock
Motorised
Valve
DHW Output
N
E
L
To Boiler
Electrical
Specification
and Wiring
(Thermostat
Control)
-
The
cylinder control
thermostat
is mounted
at
the
top of the unit
in a housing with
cable
entry
point.
-
The
unit houses
two thermostats,
a control
thermostat
and
an overheat
thermostat.
Operation of
either thermostat
must
cease
the supply
of heat
to the cylinder.
-
Remove
the thermostat
housing
cover. Wire
the
two thermostats
inside in
series
to the
hot
water
control valve as
shown
below. Electrical
5pecification
and Wiring
(Thermostat
Control)
for additional
heat source refer
to the suppliers
manual.
However,
the manual reset
limit ther
mostat
should be
used to isolate
any further
supply
of
heat to the
Spa.
9. Secondary
Circulation
-
A
pump
is required
together with
a non-return
valve.
-
The
pump
should be fitted with isolating
valves
on either
side and
sited
to minimise
air
accumulation
away from the high
point
of
the circuit.
An
air bleed valve may
be
located
at
1O
the
high
point.
Page view 9