Keston Combi 35kw User Manual Page 14

  • Download
  • Add to my manuals
  • Print
  • Page
    / 72
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 13
14
INSTALLATION
Keston Combi - Installation and Servicing
FLUE OUTLET
8
FLUE SYSTEM
IMPORTANT
When installing a replacement boiler a new ue system must be used. DO NOT re-use the existing boiler
ue installation.
DESIGN
Individual air supply and ue outlet pipes are used as standard.
The material approved for this application is which MUST be used is:
Marley muPVC Solvent Weld System (50mm) and Polypipe System 2000 muPVC solvent weld
(50mm), to BS5255 and/or BSEN1566-11 and BSEN1329, are the only systems approved for this
application.
Thefollowingpipeandttingsareapproved.
Polypipe System 2000 muPVC solvent Weld System (50mm)
Poly Pipe Code
MU 301 4m length muPVC wastepipe 5/225
MU 313 50mm x 45 deg muPVC obtuse bend
MU 314 50mm x 92.5 deg muPVC swept bend
MU 310 50mm muPVC straigh coupling
MU 316 50mm x 92.5 deg muPVC swept pipe
Marley muPVC Solvent Weld System (50mm)
Marley Code
KP 304 50mm x 4m double spigot pipe
KP32 50mm x 45 deg bend
KSC3 50mm straight coupling
KB3 50mm x 88.5 deg bend
KT3 50mm swept tee
Consideration MUST be given to expansion and contraction of the ue. Refer to Assembly Practice Frame in this installation and
Servicing Instructions for further guidance.
continued............