INSTALLATION
Keston Combi - Installation and Servicing
29
EXTERNAL ELECTRICAL CONTROLS
Wiring External to the Boiler
The fuse rating should be 3A.
Wiring external to the boiler MUST be in accordance with
the current I.E.E. (BS.7671) Wiring Regulations and any
local regulations.
Frost Protection
If parts of the pipework run outside the house or if the
boiler will be left off for more than a day or so then a frost
thermostat should be wired into the system.
This is usually done at the programmer, in which case the
programmer selector switches are set to OFF and all the
other controls MUST be left in the running position.
The frost thermostat should be sited in a cold place but
where it can sense heat from the system.
Note. If the boiler is installed in a garage it may be
necessary to t a pipe thermostat, preferably on the return
pipework.
Earths are not shown for clarity but must never be
omitted.
OpenTherm Programmable Room Temperature Control
Note. These terminals MUST ONLY be connected to an
OpenTherm Controller, (such as the Keston Chronothern Room
Controller (c.17.4.21.00.0). Connecting any other device /
control wiring may destroy the primary PCB.
1. Isolate the mains supply to the boiler.
2. Remove the front panel. Refer to Frame 39.
3. Swing the control box down into the servicing position. Refer
to Frame 45.
4. Remove the control box cover. Refer to Frame 57, no’s 3
and 4.
5. Unclip the 3 way in-line connector containing 2 purple wires
and 2 red wires.
6. Connect this 3 way connector to the 3 way connector
containing 2 purple wires wired from the 4 way terminal
block.
7. Connect the two wires from the OpenTherm Programmable
Room Temperature Control to the two LH connections of the
terminal block as shown.
8. Re-assemble in reverse order.
5
6
7
3G9990a
LN
Room Stat Frost Stat
Mains In
Programmable Room Stat
LN
Room Stat Frost Stat
Mains In
Use of General Live for Room Stat
Programmable
Room
Stat
Room
Stat
Optional
Frost Stat
Optional
Frost Stat
INSTALLATION